58 100-214-251 REV. 05
** The default Start setting is “Standard”.
Figure 4.15Type 2 DIP Switch Marked “ON” on face of Switch, Default Settings.
Options for Setting the Type 2 Switch Select Block
Auto Seek Duration – Indicates the length of
time the Auto Seek function is active.
3 – Down (500 ms)
3 – Up (100 ms)
Store at End of Weld – Updates horn frequency
memory at the end of each weld.
4 – Down (Off)
4 – Up (On)
Amplitude
Control
Set for Fixed 100% Amplitude, Variable turned
Off
6 – Down (Off)
Start
Short – Sets ramp time to 10 ms.
7 – Down
8 – Down
Medium – Sets ramp time to 35 ms.
7 – Up
8 – Down
Standard** – Sets ramp time to 80 ms.
7 – Down
8 – Up
Long – Sets ramp time to 105 ms.
7 – Up
8 – Up
NOTICE
Toggle 5 is not used.
Table 4.6 Options for Setting the Type 2 Switch Select Block
Functions Options Set Toggle
Seek
Seek on power up – Checks horn frequency upon
power up and stores it in memory.
1 – Down (Off)
1 – Up (On)
Table 4.5 Options for Setting the Type 1 Switch Select Block
Function Option Set Toggles
100-214-251 IWoper.book Page 58 Friday, June 16, 2017 4:12 PM