EasyManua.ls Logo

Emerson Branson 2000 Series - Figure 4.14 Type 1 DIP Switch Marked OPEN on Top of Switch, Default Settings; Table 4.5 Options for Setting the Type 1 Switch Select Block

Emerson Branson 2000 Series
135 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
100-214-251 REV. 05 57
4.5.7 Power Supply Module Options DIP Switch
DIP switch changes the Seek and Start functions and can affect the Amplitude Control
functions.
There are two DIP switches that Branson uses interchangeably. The following Figures
illustrate each of them. Default operational settings are provided in the Tables.
Figure 4.14Type 1 DIP Switch Marked “OPEN” on Top of Switch, Default Settings.
CAUTION General Warning
The components in the Power Supply section of the Integrated
Welder are subject to damage from electro-static discharge. When
working inside the Integrated Welder, use a grounded wrist strap and
minimize your movement to reduce the possibility of damage due to
static electricity.
WARNING General Warning
Unplug the welder (if previously connected) and wait at least two (2)
minutes before opening the case. Hazardous Voltages exist and are
stored in the system.
NOTICE
Toggle 5 is not used
Table 4.5 Options for Setting the Type 1 Switch Select Block
Function Option Set Toggles
Seek
Seek on power up Checks horn frequency upon
power up and stores it in memory.
1 – Down (Off)
1 – Up (On)
Auto SeekChecks horn frequency once each
minute, timed from the last activation of
ultrasonics.
2 – Down (Off)
2 – Up (On)
100-214-251 IWoper.book Page 57 Friday, June 16, 2017 4:12 PM