EasyManua.ls Logo

Emerson Branson 2000 Series - Page 39

Emerson Branson 2000 Series
135 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30 100-214-251 REV. 05
2.7.5 WELD ON Signal - Alarm Connector
The WELD ON signal indicates you are in the Weld Time portion of the cycle and that TRS
is active. This signal indicates when a start signal can be released.
In any of he following situations, an error will be generated:
The input becomes inactive while the welder is in the READY state
The input does not become inactive within 4 seconds after the solenoid valves are activated
The input becomes active before weld timing begins during a weld cycle
The input does not become active within 4 seconds after the solenoid valves are deactivated
100-214-251 IWoper.book Page 30 Friday, June 16, 2017 4:12 PM

Table of Contents

Related product manuals