Emerson FB2200 Flow Computer Instruction Manual
D301784X012
March 2019
Service and Troubleshooting 95
5.
Close the enclosure.
5.5 Replacing the Main Battery Pack
Periodically you must replace the main battery pack.
Figure 5-5. Main Battery Pack
The device provides a battery cable with two pairs of battery connectors, enabling you to hot-swap
the battery pack in a non-hazardous location. You attach the new battery pack to the free
connector (leaving the old one connected), and then disconnect the old battery pack.
DANGER
EXPLOSION HAZARD: Ensure the area in which you perform this operation is non-hazardous.
Performing this operation in a hazardous area could result in an explosion.