EasyManua.ls Logo

Emerson Daniel 3414 - Page 84

Emerson Daniel 3414
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 3-20:
A. Non-terminal end of Transmitter Electronics Enclosure
B. Power Supply board
C. I.S. Barrier board (inside the Guide Plate)
D. Acquisition cable
E. Backplane board
6. Use a 3 mm flat head screw driver and disconnect the Acquisition Cable terminal
block from the Backplane. Unplug the Acquisition Cable from the Backplane.
7. Remove the Power Supply (if it was not removed with the Backplane board) and I.S.
Barrier boards from the enclosure. The I.S. Barrier Board has a notched tab that
secures the board to the Guide Plate.
8. Attach the Acquisition Cable terminal block to the new Backplane Board and plug
the Power Supply Board and I.S. Barrier board into the Backplane board.
9. Insert the Backplane (with the Power Supply and I.S. Barrier Boards attached to the
Backplane) into the enclosure.
Meter repairs
74 Gas Ultrasonic Flow Meters

Table of Contents

Other manuals for Emerson Daniel 3414

Related product manuals