Only use slings with ratings that exceed the weight to be lifted. Reference your
company's standards for safety factors that must be included when calculating the load
rating.
If the slings do come in contact with the electronics, use a spreader bar on the sling to
prevent contact with the electronics.
Important
Never allow the slings to come in contact with the electronics enclosure. Damage to the
enclosure may occur.
Figure 4-2: Incorrect sling attachment
CAUTION
LIFTING HAZARD
Lifting the turbine meter with the upper enclosure installed but without the bolts
installed, may cause the electronics to fall.
Doing this may cause injury and/or damage the equipment.
Never apply shock loads to the turbine meter. Always lift the turbine meter gradually. If
shock loading occurs, inspect the slings per manufacturer's recommendations prior to
further use.
Prepare the turbine meter for use User manual
March 2019 P/N 3-9008-515
60 Daniel Series 1500 Liquid Turbine Meter, NPS 3-24

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Daniel Series and is the answer not in the manual?

Emerson Daniel Series Specifications

General IconGeneral
TypeFlow Meter
Repeatability±0.1% of reading
Communication ProtocolHART, Modbus, Foundation Fieldbus
Output4-20 mA, pulse, frequency
Process ConnectionFlanged, wafer, threaded
MaterialStainless steel, carbon steel, Hastelloy
Operating Temperature-40°C to +85°C (-40°F to +185°F)
Protection RatingIP67, NEMA 4X