4.3 Configuration of the turbine meter
The Daniel factory configures the turbine meter internal components. Inspect the internal
components before installation.
4.3.1 Orientation and position of the turbine meter
Flow direction
Turbine meters can be used for uni-directional or bi-directional flows. The design of the
internal features of the meter housing and the internal components depend on the
desired configuration. Install the LTM carefully so it complies with the correct inlet and
outlet sides (See label on the turbine meter for inlet direction).
Flow conditioning
The flow stream must be free of swirl for a turbine meter to perform consistently and
accurately. The internal assembly supports of a turbine meter offer a slight straightening
effect. If additional flow conditioning is required, use straightening vanes or tube bundles.
Refer to API MPMS, Chapter 5, Section 3.
A flow conditioning plate is available for all standard series 1500 LTM, NPS 3 through 8. It is
designed to eliminate product flow characteristics such as liquid swirl and non-uniform
velocity profiles (induced by piping configurations and other elements of the system) that
may impede accurate measurement within the turbine meter run.
The plate is installed directly into the inlet of the turbine meter. Due to the flow
conditioning influence on the incoming product, the need for upstream flow straightening
piping is reduced. It is recommended that a minimum of five pipe diameters be
maintained upstream and downstream of the turbine meter to ensure accurate operation.
Actual length is determined by piping requirements specific to the application.
User manual Prepare the turbine meter for use
P/N 3-9008-515 March 2019
User manual 61

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Daniel Series and is the answer not in the manual?

Emerson Daniel Series Specifications

General IconGeneral
TypeFlow Meter
Repeatability±0.1% of reading
Communication ProtocolHART, Modbus, Foundation Fieldbus
Output4-20 mA, pulse, frequency
Process ConnectionFlanged, wafer, threaded
MaterialStainless steel, carbon steel, Hastelloy
Operating Temperature-40°C to +85°C (-40°F to +185°F)
Protection RatingIP67, NEMA 4X
Fluid CompatibilityLiquids, gases

Related product manuals