4.2 Lifting requirements for personnel
WARNING
EQUIPMENT HANDLING AND OPERATING HAZARD
Wear personal protective equipment appropriate to the situation when working with
the turbine meter. Adhere to all safety standards and best practices for operating the
equipment.
Failure to comply may result in death or serious injury.
Best lifting practices
WARNING
LIFTING HAZARD
The lifting instructions are for installation and removal of the Daniel Liquid Turbine
Meter only and do not address lifting the turbine meter while it is attached or bolted to
piping.
Failure to comply with these instructions may result in death, serious injury, or
equipment damage.
4.2.1
Equipment required to lift the turbine meter
WARNING
CRUSHING HAZARD
During turbine meter installation or removal, always place the unit on a stable platform
or surface that supports its assembled weight.
Failure to comply could allow the turbine meter to roll, resulting in death, serious injury
or equipment damage.
Important
Prior to lifting the unit refer to Minimum clearances for installation, operation and
maintenance for the assemble weight.
The following instructions provide general guidelines using lifting slings only on the Daniel
turbine meter. Use appropriately rated lifting slings when lifting the turbine meter.
Prepare the turbine meter for use User manual
March 2019 P/N 3-9008-515
58 Daniel Series 1500 Liquid Turbine Meter, NPS 3-24

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Daniel Series and is the answer not in the manual?

Emerson Daniel Series Specifications

General IconGeneral
TypeFlow Meter
Repeatability±0.1% of reading
Communication ProtocolHART, Modbus, Foundation Fieldbus
Output4-20 mA, pulse, frequency
Process ConnectionFlanged, wafer, threaded
MaterialStainless steel, carbon steel, Hastelloy
Operating Temperature-40°C to +85°C (-40°F to +185°F)
Protection RatingIP67, NEMA 4X
Fluid CompatibilityLiquids, gases

Related product manuals