Minimum clearances for installation, operation and
maintenance
Below is the approximate shipping dimensions and weight for the Series 1500 LTM NPS
3-24. Consult the factory for certified dimension prints.
Figure 2-3: Dimensions for the Series 1500 LTM NPS 3-24
Table 2-11: Flow meter and flow straightening section dimensions for the Series 1500
LTM NPS 3-24
Size A B C
Inches mm Inches mm Inches mm
3 10 254.0 5 127.0 11 278.6
4 12 304.8 6 152.4 12 297.7
6 14 355.6 7 177.8 13 324.7
8 16 406.4 8 203.2 14 350.1
10 20 508.0 10 254.0 15 377.1
12 24 609.6 12 304.8 16 402.5
16 32 812.8 16 406.4 17 443.7
18 36 914.4 18 457.2 18 469.1
20 40 1016 20 508 19 494.5
24 48 1219 24 610 21 545.3
Table 2-12: Flow meter and flow straightening section dimensions for the Series 1500
LTM NPS 3-24
Size D E F
Inches mm Inches mm Inches mm
3 30 762 15 381 55 1397.0
4 40 1016 20 508 72 1828.8
6 60 1524 30 762 104 2641.6
Operating conditions and specifications User manual
March 2019 P/N 3-9008-515
52 Daniel Series 1500 Liquid Turbine Meter, NPS 3-24

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Daniel Series and is the answer not in the manual?

Emerson Daniel Series Specifications

General IconGeneral
TypeFlow Meter
Repeatability±0.1% of reading
Communication ProtocolHART, Modbus, Foundation Fieldbus
Output4-20 mA, pulse, frequency
Process ConnectionFlanged, wafer, threaded
MaterialStainless steel, carbon steel, Hastelloy
Operating Temperature-40°C to +85°C (-40°F to +185°F)
Protection RatingIP67, NEMA 4X
Fluid CompatibilityLiquids, gases