Important
The security latch prevents the removal of the LME cover in a flameproof
environment.
3. Unscrew the end cap and remove it from the housing.
4. Unplug one or two ¾-14 NPT ports (as required) and install the conduit (provided by
the customer) to the enclosure and tighten.
5. Install the electronics according to Wiring and cable connections. Consult with
Daniel if the preamplifier acquired is other than a dual channel preamplifier.
WARNING
SHOCK AND EXPLOSION HAZARD
Verify that the LME and/or RME is grounded.
Failure to comply may cause death, serious injury and/or equipment damage.
6. Screw the end cap to the housing. Hand-tighten, only if required.
7. Install the security latch.
User manual Installation procedure
P/N 3-9008-515 March 2019
User manual 75

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Daniel Series and is the answer not in the manual?

Emerson Daniel Series Specifications

General IconGeneral
TypeFlow Meter
Repeatability±0.1% of reading
Communication ProtocolHART, Modbus, Foundation Fieldbus
Output4-20 mA, pulse, frequency
Process ConnectionFlanged, wafer, threaded
MaterialStainless steel, carbon steel, Hastelloy
Operating Temperature-40°C to +85°C (-40°F to +185°F)
Protection RatingIP67, NEMA 4X
Fluid CompatibilityLiquids, gases

Related product manuals