134 Digitax ST User Guide
Issue Number: 5
*For more information, refer to section 12.22.5 Stop modes on page 169.
**For more information, refer to section 12.22.6 Line power supply loss modes on page 169.
***For more information, refer to section 12.22.7 Start / stop logic modes on page 170.
Parameter
Range(
Ú) Default(Ö)
Type
6.01 Stop mode COASt (0), rP (1), no.rP (2) no.rP (2) RW Txt US
6.03 Line power supply loss mode diS (0), StoP (1), ridE.th (2) diS (0) RW Txt US
6.04 Start / stop logic select 0 to 4 4 RW Uni US
6.08 Hold zero speed OFF (0) or On (1) On (1) RW Bit US
6.09 Catch a spinning motor 0 to 1 1 RW Uni US
6.12 Enable stop key OFF (0) or On (1) OFF (0) RW Bit US
6.13 Enable forward / reverse key {0.28} OFF (0) or On (1) OFF (0) RW Bit US
6.15 Drive enable OFF (0) or On (1) On (1) RW Bit US
6.16 Electricity cost per kWh 0.0 to 600.0 currency units per kWh 0 RW Uni US
6.17 Reset energy meter OFF (0) or On (1) OFF (0) RW Bit NC
6.18 Time between filter changes 0 to 30,000 hrs 0 RW Uni US
6.19
Filter change required /
change done
OFF (0) or On (1) OFF (0) RW Bit PT
6.20 Powered-up time: years.days 0 to 9.364 years.days
RW Uni NC PT
6.21
Powered-up time:
hours.minutes
0 to 23.59 hours.minutes
RW Uni NC PT
6.22 Run time: years.days 0 to 9.364 years.days
RO Uni NC PT PS
6.23 Run time: hours.minutes 0 to 23.59 hours.minutes
RO Uni NC PT PS
6.24 Energy meter: MWh ±999.9 MWh
RO Bi NC PT PS
6.25 Energy meter: kWh ±99.99 kWh
RO Bi NC PT PS
6.26 Running cost ±32,000
RO Bi NC PT
6.27 Time before filter change due 0 to 30,000 hrs
RO Uni NC PT PS
6.28
Select clock for trip log time
sampling
OFF (0) or On (1) OFF (0) RW Bit US
6.29 Hardware enable OFF (0) or On (1)
RO Bit NC PT
6.30 Sequencing bit: Run forward OFF (0) or On (1) OFF (0) RW Bit NC
6.31 Sequencing bit: Jog forward OFF (0) or On (1) OFF (0) RW Bit NC
6.32 Sequencing bit: Run reverse OFF (0) or On (1) OFF (0) RW Bit NC
6.33
Sequencing bit: Forward /
reverse
OFF (0) or On (1) OFF (0) RW Bit NC
6.34 Sequencing bit: Run OFF (0) or On (1) OFF (0) RW Bit NC
6.35 Forward limit switch OFF (0) or On (1) OFF (0) RW Bit NC
6.36 Reverse limit switch OFF (0) or On (1) OFF (0) RW Bit NC
6.37 Sequencing bit: Jog reverse OFF (0) or On (1) OFF (0) RW Bit NC
6.39 Sequencing bit: Not stop OFF (0) or On (1) OFF (0) RW Bit NC
6.40 Enable sequencer latching OFF (0) or On (1) OFF (0) RW Bit US
6.41 Drive event flags 0 to 65,535 0 RW Uni NC
6.42 Control word 0 to 32,767 0 RW Uni NC
6.43 Control word enable OFF (0) or On (1) OFF (0) RW Bit US
6.44 Active supply OFF (0) or On (1)
RO Bit NC PT
6.45
Force cooling fan to run at full
speed
OFF (0) or On (1) OFF (0) RW Bit US
6.46 Normal low voltage supply 48 V to 72 V 48 RW Uni PT US
6.47
Disable line power supply/
phase loss detection from
input rectifier
OFF (0) or On (1) OFF (0) RW Bit US
6.48
Line power supply loss ride
through detection level
0 to DC_VOLTAGE_SET_MAX V 200 V drive: 205, 400 V drive: 410 RW Uni RA US
6.49
Disable multi-module drive
module number storing on trip
OFF (0) or On (1) OFF (0) RW Bit US
6.50 Drive comms state drv (0), SLot 1(1), SLot 2 (2)
RO Txt NC PT
6.51 External rectifier not active OFF (0) or On (1) OFF (0) RW Bit
RW Read / Write RO Read only Uni Unipolar Bi Bi-polar Bit Bit parameter Txt Text string
FI Filtered DE Destination NC Not copied RA Rating dependent PT Protected US User save PS Power down save