1592026260 IEV22-24D GB r.1.0 21.02.2019 IEV 44/60
LAN address (used only if connected to the
IC200 EVO)
Firmware release (only reading)
Type of current valve 1: peak or RMS
0= peak
1= RMS
(this value is set automatically by the controller
if EC9> 0)
Type of signal valve 1: microstepping o normal
mode
0= microstepping
1= normal mode
(this value is set automatically by the controller
if EC9> 0)
Type of current valve 2: peak or RMS
0= peak
1= RMS
(this value is set automatically by the controller
if EC18> 0)
Type of signal valve 2: microstepping o normal
mode
0= microstepping
1= normal mode
(this value is set automatically by the controller
if EC18> 0)
Number of available gases selectable by Ec8
parameter.
This is an only reading parameter, used to
define the maximum value of Ec8 parameter.
Password to enter in Pr2 level and password to
reset the alarm log
Number of steps the valve has to move before
compressor start-up.
0 = function is disabled
Sets valve manual operation mode
0= Automatic
1= Manual (valve is open to Et3 steps)
Absolute number of steps the valve has to
move in manual mode
Number of steps the valve has to move before
compressor start-up.
0 = function is disabled
Sets valve manual operation mode
0= Automatic
1= Manual