9
August 2017
Installation and Maintenance Manual
E2K-402-0817 Rev. 2
Assembly to Valves
Figure 5 Full MCP Frame
(4)
Type M/MG
(side mount)
(3)
(2)
(1)
EIM Modular Control Package (MCP) is available congured in thousands of possible
combinations of electrical and electronic parts. Refer to WIRING DIAGRAM and EIM JOB
SPEC SHEET provided by EIM with each actuator.
Back out two Stopbolts (1) to allow valve to close and open fully.
Set Travel Limit Switches (see pg. 4).
1. Run actuator electrically to full Close.
2. Screw Close (1) Stopbolt in until it seats, then back off 1/2 turn. Tighten (2)
Lockscrew.
3. Run actuator electrically to full Open.
4. Screw Open (1) Stopbolt in until it seats; back off 1/2 turn. Tighten Locknut.
5. Install (3) & (4) Seal Washer & Screw.
CAUTION:
Do not set actuator position Limit Switches to drive into mechanical stops.
Damage can occur if unit is repeatedly stalled into end stops.
Section 3: Assembly to Valves