EasyManua.ls Logo

Emerson IC695PNS001-BHBF1 2 - Page 5

Emerson IC695PNS001-BHBF1 2
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GFK-2738AE Jan 2024
2
Specifications
Descriptions
Power Requirements
PNS001-Bxxx or later:
PNS101-Axxx or later:
3.3 Vdc
0.6 A with no SFP devices installed
1.3 A maximum (two SFP devices
installed, 0.35A per SFP)
PNS001-Bxxx or later:
PNS101-Axxx or later:
5Vdc: 0.7 A maximum
Operating Temperature
Range
PNS001-Bxxx or later:
PNS101-Axxx or later:
-25°C to 60°C
Derated to 57°C:
• If 100MB Fiber SFPs are installed, or
• If Copper SFPs operating at 1GB
Number of Port Connectors
Two RJ-45 and Two SFP Cages (SFP devices not included, available separately)
FW Upgrade Connector
PNS001-Bxxx & PNS101-Axxx:
One RJ-45 Ethernet connector on the front
panel
SD Card
Supports SD and SDHC cards.
PNS001 Status and Control
Bits
32 input status bits and 32 output control bits
PROFINET I/O production
rate (I/O Update Rate)
Configurable selections: 1ms, 2ms, 4ms, 8ms, 16ms, 32ms, 64ms, 128ms, 256ms or
512ms
Number of IP addresses
PNS001-Bxxx & PNS101-Axxx: Two
One for PROFINET ports.
One for the front panel port. Supports
Classless Inter-Domain Routing (CIDR)
Number of MAC Addresses
PNS001-Bxxx & PNS101-Axxx: Six
One front panel port, one for each of the
four external ports, and one internal port.
I/O Station Maximum Limits
Number of I/O Modules per station
I/O data per station
Configuration
V2.3 GSDML file is available for download and import into PAC Machine Edition. Please
see the support link at the end of this document. The GSDML supporting a firmware release
is part of the firmware upgrade kit available on the Support website.
For installation and maintenance requirements, refer to PACSystems RX3i Installation and Maintenance
Requirements, GFK-2975.