54 Powerdrive F300 Getting Started Guide
Issue Number: 5
6 Basic parameters (Menu 0)
Parameter
Range Default
Type
OL RFC-A RFC-S OL RFC-A RFC-S
00.001
Minimum Reference
Clamp
{01.007} ±VM_NEGATIVE_REF_CLAMP1 Hz / rpm 0 Hz / rpm RW Num US
00.002
Maximum
Reference Clamp1
{01.006} ±VM_POSITIVE_REF_CLAMP1 Hz / rpm
50 Hz: 50.0 Hz
60 Hz: 60.0 Hz
50 Hz: 1500.0
rpm
60 Hz: 1800.0
rpm
RW Num US
00.003 Acceleration Rate 1 {02.011}
±VM_ACCEL_RATE
s to Pr 01.006
±VM_ACCEL_RATE
s to Pr 01.006
20.0 s
to Pr 01.006
20.000 s
to Pr 01.006
RW Num US
00.004 Deceleration Rate 1 {02.021}
±VM_ACCEL_RATE
s to Pr 01.006
±VM_ACCEL_RATE
s to Pr 01.006
20.0 s
to Pr 01.006
20.000 s
to Pr 01.006
RW Num US
00.005 Reference Selector {01.014}
A1 A2 (0),A1 Preset (1), A2 Preset (2),
Preset (3), Keypad (4), Precision (5),
Keypad Ref (6)
A1 A2 (0) RW Txt US
00.006
Symmetrical
Current Limit
{04.007} ±VM_MOTOR1_CURRENT_LIMIT % 110.0 % 110.0 % RW Num RA US
00.007
Open-loop Control
Mode / Action On
Enable
{05.014}
Ur S (0),Ur (1),
Fixed (2),
Ur Auto (3),
Ur I (4), Square (5),
Current 1P (6)
Ur I (4) RW Txt US
Speed Controller
Proportional Gain
Kp1
{03.010}
0.0000 to 200.000
s/rad
0.0300 s/rad RW Num US
00.008
Low Frequency
Voltage Boost
{05.015} 0.0 to 25.0 %
3.0 % RW Num US
Speed Controller
Integral Gain Ki1
{03.011}
0.00 to 655.35
s
2
/rad
0.10 s
2
/rad
RW Num US
00.009
Dynamic V to F
Select
{05.013} Off (0) or On (1)
Off (0) RW Bit US
Speed Controller
Differential
Feedback Gain Kd
1
{03.012}
0.00000 to 0.65535
1/rad
0.00000 1/rad RW Num US
00.010
Motor Rpm {05.004} ±180000 rpm
RO Num ND NC PT FI
Speed Feedback {03.002}
±VM_SPEED rpm RO Num ND NC PT FI
00.011 Output Frequency {05.001} ±VM_SPEED_FREQ_REF Hz
RO Num ND NC PT FI
00.012 Current Magnitude {04.001} ±VM_DRIVE_CURRENT_UNIPOLAR A
RO Bit ND NC PT FI
00.013
Torque Producing
Current
{04.002} ±VM_DRIVE_CURRENT A
RO Bit ND NC PT FI
00.015 Ramp Mode Select {02.004}
Standard (1),
Std boost (2)
Standard (1) Standard (1) RW Txt US
00.017
Digital Input 6
Destination
{08.026} 0.000 to 59.999
0.000 RW Num DE PT US
Current Reference
Filter 1 Time
Constant
{04.012}
0.0 to 25.0 ms 1.0 ms RW Num US
00.019
Analog Input 1
Mode
{07.007}
4-20mA Low (-4), 20-4mA Low (-3),
4-20mA Hold (-2), 20-4mA Hold (-1),
0-20mA (0), 20-0mA (1), 4-20mA Trip (2),
20-4mA Trip (3), 4-20mA (4), 20-4mA (5),
Volt (6), Therm Short Cct (7), Thermistor (8),
Therm No Trip (9)
4-20mA (4) RW Txt US
00.020
Analog Input 1
Destination
{07.010} 00.000 to 59.999 01.036 RW Num DE PT US
00.021
Analog Input 2
Mode
{07.011}
4-20mA Low (-4), 20-4mA Low (-3),
4-20mA Hold (-2), 20-4mA Hold (-1),
0-20mA (0), 20-0mA (1), 4-20mA Trip (2),
20-4mA Trip (3), 4-20mA (4), 20-4mA (5),
Volt (6), Therm Short Cct (7), Thermistor (8),
Therm No Trip (9)
Volt (6) RW Txt US