Table 7-5 Dyneo LSRPM 2400 rpm motors
* From firmware version 01.12.xx.xx onwards, the rated current from the motor nameplate is entered
into Pr 05.007 / Pr 00.046 and will be updated automatically to the sensorless value after an
autotune.
LSRPM Motor model
Motor rated
current
(nameplate
value)
Pr 00.046
*
Sensorless
motor rated
current after
autotune
*
Switching
frequency
Pr 00.041
Ke
Pr 00.047
Motor
Thermal
Time
Constant
Pr 00.053
A A kHz V/1000 rpm s
2400 LSRPM 90SL 4.8 kW 9.1 9.4 4 145 850
2400 LSRPM 100L 7.2 kW 13.4 13.4 4 146 850
2400 LSRPM 100L 9.5 kW 17.7 17.7 4 151 850
2400 LSRPM 132M 13.1 kW 25.0 27.2 8 149 1050
2400 LSRPM 132M 16.3 kW 31.0 32.1 8 140 1050
2400 LSRPM 132M 19.2 kW 37.0 37.1 8 152 1050
2400 LSRPM 160MP 25 kW 47.0 47.0 8 153 1050
2400 LSRPM 160MP 31 kW 58.0 58.0 8 156 1050
2400 LSRPM 160LR 36 kW 69.0 69.0 8 156 1050
2400 LSRPM 200L 50 kW 110 110 4 136 900
2400 LSRPM 200L1 65 kW 137 137 4 128 900
2400 LSRPM 200L1 80 kW 160 164 4 145 900
2400 LSRPM 225MR1 100 kW 200 201 4 142 900
2400 LSRPM 250SE 125 kW 235 240 4 146 1150
2400 LSRPM 250ME 150 kW 285 288 4 146 1150
2400 LSRPM 280SD1 190 kW 350 361 4 152 1150
2400 LSRPM 280MK1 230 kW 429 429 4 147 2600