Powerdrive F300 Getting Started Guide 77
Issue Number: 5
Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting started
Basic parameters
(Menu 0)
Running the
motor
Optimization
NV Media Card
Operation
Further
information
UL listing
information
Table 7-6 Dyneo LSRPM 3000 rpm motors
* From firmware version 01.12.xx.xx onwards, the rated current from the motor nameplate is entered
into Pr 05.007 / Pr 00.046 and will be updated automatically to the sensorless value after an
autotune.
LSRPM Motor model
Motor rated
current
(nameplate
value)
Pr 00.046
*
Sensorless
motor rated
current after
autotune
*
Switching
frequency
Pr 00.041
Ke
Pr 00.047
Motor
Thermal
Time
Constant
Pr 00.053
A A kHz V/1000 rpm s
3000 LSRPM 90SL 5.8 kW 11.0 11.1 4 120 850
3000 LSRPM 100L 8.7 kW 16.2 16.2 4 131 850
3000 LSRPM 100L 11.6 kW 21.0 21.0 4 134 850
3000 LSRPM 132M 15.8 kW 30.0 31.8 8 121 1050
3000 LSRPM 132M 19.7 kW 38.0 38.0 8 121 1050
3000 LSRPM 132M 23 kW 44.0 44.0 8 126 1050
3000 LSRPM 160MP 30 kW 57.0 57.0 8 127 1050
3000 LSRPM 160MP 37 kW 67.8 67.8 8 128 1050
3000 LSRPM 160LR 44 kW 82.0 82.0 8 129 1050
3000 LSRPM 200L 50 kW 111 116 4 109 900
3000 LSRPM 200L1 65 kW 126 136 4 118 900
3000 LSRPM 200L1 85 kW 170 170 4 125 900
3000 LSRPM 225ST2 110 kW 215 219 4 118 900
3000 LSRPM 250SE 145 kW 285 285 4 114 1150
3000 LSRPM 250ME1 170 kW 338 344 4 111 1150
3000 LSRPM 280SD1 200 kW 365 365 4 126 1150
3000 LSRPM 280SD1 220 kW 370 398 4 130 1150
Powerdrive F300 Getting Started Guide English Iss2.book Page 77 Tuesday, July 28, 2015 3:23 PM