EasyManua.ls Logo

Emerson Powerdrive F300 - Page 79

Emerson Powerdrive F300
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Powerdrive F300 Getting Started Guide 79
Issue Number: 5
Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting started
Basic parameters
(Menu 0)
Running the
motor
Optimization
NV Media Card
Operation
Further
information
UL listing
information
Table 7-9 Dyneo LSRPM 5500 rpm motors
* From firmware version 01.12.xx.xx onwards, the rated current from the motor nameplate is entered
into Pr 05.007 / Pr 00.046 and will be updated automatically to the sensorless value after an
autotune.
LSRPM Motor model
Motor rated
current
(nameplate
value)
Pr 00.046
*
Sensorless
motor rated
current after
autotune
*
Switching
frequency
Pr 00.041
Ke
Pr 00.047
Motor
Thermal
Time
Constant
Pr 00.053
A A kHz V/1000 rpm s
5500 LSRPM 132M 18.6 kW 35.0 35.0 8 74 1050
5500 LSRPM 132M 23 kW 44.0 44.0 8 74 1050
5500 LSRPM 132M 27 kW 52.0 52.0 8 77 1050
5500 LSRPM 160MP 35 kW 67.0 67.0 8 76 1050
5500 LSRPM 160MP 44 kW 82.0 82.0 8 77 1050
5500 LSRPM 160LR 52 kW 97.0 97.0 8 77 1050
5500 LSRPM 200L1 70 kW 140 141 8 68 900
5500 LSRPM 200L1 85 kW 170 170 8 64 900
5500 LSRPM 200L1 100 kW 210 210 8 64 900
5500 LSRPM 200L2 140 kW 265 296 8 67 900
Powerdrive F300 Getting Started Guide English Iss2.book Page 79 Tuesday, July 28, 2015 3:23 PM