Section 1: Introduction
February 2013
Introduction
Example
The transmitter specification limit is 185 °F (85 °C). If the ambient temperature is 131 °F (55 °C)
and the maximum process temperature to be measured is 1500 °F(815 °C), the maximum
permissible connection head temperature rise is the transmitter specification limit minus the
ambient temperature (moves 185 °F to 131 °F [85 to 55 °C]), or 86 °F (30 °C).
In this case, an extension of 5-in. (0.13 m) meets t his requirement, but 6-in. (0.15 m) provides
an additional margin of protection, thereby reducing risk of ambient thermal damage.
Temperature Limits
1.5 Service Support
To expedite the return process outside of North America, contact your Emerson Process
Management representative,
Within the United States, call the Emerson Process Management Response Center toll-free
number 1 800 654 7768. The center, which is available 24 hours a day, will assist you with any
needed information or materials.
The center will ask for product model and serial numbers, and will provide a Return Material
Authorization (RMA) number. The center will also ask for the process material to which the
product was last exposed.
Operating Limit Storage Limit
With LCD Display -4 to 175 °F
-20 to 80 °C
-40 to 185 °F
-40 to 85 °C
Without LCD Display -40 to 185 °F
-40 to 85 °C
-40 to 185 °F
-40 to 85 °C
Individuals who handle products exposed to a hazardous substance can avoid injury if they
are informed of, and understand, the hazard. If the product being returned was exposed to
a hazardous substance as defined by OSHA, a copy of the required Material Safety Data
Sheet (MSDS) for each hazardous substance identified must be included with the returned
goods.