Rosemount 8600 Vortex Flow Meter
2.3.10 Auto adjust filter
The Auto Adjust Filter is a function that can be used to optimize the range of the flowmeter
based on the density of the fluid. The electronics uses process density to calculate the
minimum measurable flow rate, while retaining at least a 4:1 signal to the trigger level
ratio. This function will also reset all of the filters to optimize the flowmeter performance
over the new range. If the configuration of the device has changed, this method should be
executed to ensure the signal processing parameters are set to their optimum settings. For
a stronger signal select a density value that is lower than the actual flowing density.