Unidrive M600 Getting Started Guide 49
Issue Number: 2
Safety information Product information
Mechanical
installation
Electrical installation Getting started
Basic parameters
Running the motor
NV Media Card
Operation
Further information
6.1 Parameter descriptions
6.1.1 Pr mm.000
Pr mm.000 is available in all menus, commonly used functions are provided as text strings in
Pr mm.000 shown in Table 6-1. The functions in Table 6-1 can also be selected by entering the
appropriate numeric values (as shown in Table 6-2) in Pr mm.000. For example, enter 4001 in
Pr mm.000 to erase the file in NV media card location 001.
Table 6-1 Commonly used functions in Pr mm.000
String Action
Save parameters
Save parameters when under voltage is not active and low voltage threshold is not
active
Load file 1 Load the drive parameters or user program file from NV media card file 001
Save to file 1 Transfer the drive parameters to parameter file 001
Load file 2 Load the drive parameters or user program file from NV media card file 002
Save to file 2 Transfer the drive parameters to parameter file 002
Load file 3 Load the drive parameters or user program file from NV media card file 003
Save to file 3 Transfer the drive parameters to parameter file 003
Show non-default Displays parameters that are different from defaults
Destinations Displays parameters that are set
Reset 50Hz Defs Load parameters with standard (50 Hz) defaults
Reset 60Hz Defs Load parameters with US (60 Hz) defaults
Reset modules Reset all option modules
Read Enc.NP P1 No function
Read Enc.NP P2 No function
Unidrive M600 Getting Started Guide English Iss1.book Page 49 Friday, April 25, 2014 2:08 PM