Unidrive M702 Getting Started Guide 37
Issue Number: 4
Safety information Product information
Mechanical
installation
Electrical
installation
Getting started
Basic parameters
(Menu 0)
Running the motor
NV Media Card
Operation
Further information
UL listing
information
4.6 Braking resistor values
Table 4-2 Minimum resistance values and peak power rating for the braking resistor at 40 °C (104 °F)
Model
Minimum
resistance
*
Instantaneous
power rating
Continuous
power
rating
Model
Minimum
resistance
*
Instantaneous
power rating
Continuous
power
rating
Ω kW kW Ω kW kW
200 V 575 V
03200050
20 8.5
1.5 05500030
80 12.1
2.6
03200066 1.9 05500040 4.6
03200080 2.8 05500069 6.5
03200106 3.6 06500100
13 74
8.7
04200137
18 9.4
4.6 06500150 12.3
04200185 6.3 06500190 16.3
05200250 16.5 10.3 8.6 06500230 19.9
06200330
8.6 19.7
12.6 06500290 24.2
06200440 16.4 06500350 31.7
07200610
6.1 27.8
20.5 07500440
8.5 113.1
39.5
07200750 24.4 07500550 47.1
07200830 4.5 37.6 32.5 08500630
5.5 174.8
58.6
08201160
2.2 76.9
41 08500860 78.1
08201320 47.8 09501040
3.3 291.3
97.7
09201760
1.2 144.5
59.4 09501310 116.7
09202190 79.7 10501520 3.3 291.3 155.6
10202830
1.3 130
98.6 10501900 2.5 384.4 155.6
10203000 116.7 690 V
400 V 07600190
11.5 121.2
20.6
03400025
74 9.2
1.5 07600240 23.9
03400031 2.0 07600290 32.5
03400045 2.8 07600380 41.5
03400062 4.6 07600440 47.8
03400078
50 13.6
5.0 07600540 60.5
03400100 6.6 08600630
5.5 253.5
79.7
04400150
34 19.9
9.0 08600860 95.2
04400172 12.6 09601040
4.2 331.9
116.3
05400270 31.5 21.5 16.2 09601310 139.1
05400300 18 37.5 19.6 10601500 4.2 331.9 166.7
06400350
17 39.8
21.6 10601780 3.3 422.4 193
06400420 25 * Resistor tolerance: ±10 %.
06400470 32.7
07400660
9.0 75.2
41.6
07400770 50.6
07401000 7.0 96.6 60.1
08401340
4.8 140.9
81
08401570 98.6
09402000
2.4 282.9
118.6
09402240 156.9
10402700
2.6 260
198.2
10403200 237.6
Unidrive M702 Getting Started Guide English iss3.book Page 37 Friday, August 29, 2014 2:33 PM