EasyManua.ls Logo

Emerson XM678D - Page 63

Emerson XM678D
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MODBUS Termination Blocks Default Parameter Map • 55
dAo 0.0
Delay of
temperature alarm
at start
-up
0.0 to 24h00m
in
After powering the device: time interval
between the detec
tion of the
temperature alarm condit
ion and the
alarm signaling.
Format: hou
rs.10min
Resolu
tion: 10min
EdA 30
Alarm delay at the
end of defrost
0 to 255mi
n
At the end of the defrost cycle: time
interval between the detecti
on of the
temperature alarm co
ndition and the
alarm signaling.
dot 15
Temperature alarm
exclusion
after door
open
0 to 255min -
Sti nU
Stop regulation
interv
al
0.0 to 24h00min; nU
After regulating continuously for Sti
time, the valve closes
for Std time to
prevent ice from forming.
Format: hou
rs.10min
Resolu
tion: 10min
Std 1 Stop duration 1 to 255min
Defines the stop regulation time after
Sti. During t
his interval, the display
shows StP message.
tbA n
Silencing alarm
relay by pressing a
key
n; Y -
O
UTPUT CONFIGURATION
OA1 CPr
Relay on terminals
11-1
2 configuration
nU; CPr; dEF; FAn; ALr;
LiG; AUS; db; onF; AC
nU = n
ot used; CPr = compressor/
val
ve; dEF = defrost; FAn = Fan;
ALr = Alarm; LiG = L
ight;
AUS = auxi
liary; db =
heater for neutral
zone (not available with CrE = Y);
onF = ON/OFF; AC
= anti-swea
t;
E3r: solenoid valve for EX3 or for
mechanical
solenoid valve
OA6 AUS
Relay on terminals
17-1
8 configuration
nU; CPr; dEF;
FAn; ALr; LiG;
AUS; db; onF; AC
nU = n
ot used; CPr = compressor /
val
ve; dEF = defrost;
FAn =
Fan; ALr = A
larm; LiG = Light;
AUS = auxiliary; db = heater for neutral
zone (not available with CrE = Y);
onF =
ON/OFF; AC = anti-sw
eat;
E3r: solenoid valve for EX3 or for
mechanical
solenoid valve
OA7 nU Relay on terminals
nU; CPr; dEF; FAn; ALr;
LiG; AUS; db; on
F; AC
nU = n
ot used; CPr = compressor/
val
ve; dEF = defrost; FAn = Fan;
ALr = Alarm; LiG = L
ight;
AUS = auxi
liary; db =
heater for neutral
zone (not available with CrE = Y);
onF = ON/OFF; AC
= anti-swea
t;
E3r: solenoid valve for EX3 or for
mechanical
solenoid valve
Label Value Description Range Notes
Table 24-1 - Default Parameter Map

Table of Contents

Other manuals for Emerson XM678D

Related product manuals