- 125 -
Chapter 6. Connection
Note)
a) The input contact of this product can be entered from 2 types of NPN and PNP, so 2 types
of sensors such as NPN and PNP can be used for an input contact.
b) For extended I/O No.1, X2.0~X3.3 is allocated to an input contact(IN0~IN19) and Y1.0~Y1.D
is allocated to an output contact(OUT0~OUT13), and for extended I/O No.2, X4.0~X5.3 is
allocated to an input contact(IN0~IN19) and Y3.0~Y3.D is allocated to an output
contact(OUT0~OUT13).
c)
Set an ID as below with an extended I/O setup dip switch before inputting power.
Expansion I/O 1: 1 & 2 ON, 3 & 4 OFF
Expansion I/O 2: 1 & 2 OFF, 3 & 4 ON
There may be an I/O malfunction when setting other ID than above. Do not set an ID after
inputting power, so be careful.
3) Example of I/O connection
1 In INCOM0
20 In IN0
2 In IN1
21 In IN2
3 In IN3
22 In IN4
4 In IN5
23 In IN6
5 In IN7
24 In IN8
6 In IN9
25 In INCOM1
7 In IN10
26 In IN11
8 In IN12
27 In IN13
9 In IN14
28 In IN15
10 In IN16
29 In IN17
11 In IN18
30 In IN19
12 Out OUT0
31 Out OUT1
13 Out OUT2
32 Out OUT3
14 Out OUT4
33 Out OUT5
15 Out OUT6
34 Out OUT7
16 Out OUT8
35 Out OUT9
17 Out OUT10
36 Out OUT11
18 Out OUT12
37 Out OUT13
19 In OUTCOM
24V / 24V GND
IN0~ IN9
24V GND
24V GND / 24V
24V / 24V GND
IN10~ IN19
24V
OUT0~ OUT13
24V GND / 24V