Chapter 8. Alarm
Division No. Message Content and countermeasure
216 There cannot be a letter after ).
A letter unusable after) was commanded in a MACRO
operational expression.
217
There cannot be a letter after a
calculator.
A letter unusable after a calculator such as +,-
,*,/ was commanded in a MACRO operational
expression.
218
There cannot be a letter after a
constant.
A letter unusable after a constant, a number, was
commanded in a MACRO operational expression.
219
There cannot be a letter after a
variable.
A letter unusable after an E variable was commanded
in a MACRO operational expression.
220 Out of variable number range
The number of E variables in a MACRO operational
expression has exceeded the command value range.
221 No =
There is no = command in a MACRO operational
expression.
222
A computation divided by 0 was
commanded.
A command of division by ‘0’ was commanded in a
MACRO operational expression.
PLC
301 An error was found while compiling a PLC program.
302 The capacity of a PLC program has exceeded its range(about 1000 STEP).
303 No END was commanded in a PLC program.
304 There is an error in the application before or after a LOAD command in a PLC program.
305 There is an error in the application before or after a D command in a PLC program.
306 There is an error in the application before or after a AND command in a PLC program.
307 There is an error in the application before or after a NOT command in a PLC program.
308 There is an error in the application before or after a MCS command in a PLC program.
309 There is an error in the application before or after a RST command in a PLC program.
310 There is an error in the application before or after an OR command in a PLC program.
311 There is an error in the application before or after an OUT command in a PLC program.
312 There is an error in the application before or after a SET command in a PLC program.
313
There is an error in the application before or after an X, Y, M, T, C contact point in a PLC
program.
314 There is an error in the application before or after a TMR command in a PLC program.
315
The value of a designated word in a TMR command of the PLC program has exceeded its
range(0~9).
316 There is an error in the application before or after a CTR command in a PLC program.
317
The value of a designated word in a CTR command of the PLC program has exceeded its
range(0~9).
318
There is an error in the application before or after an AND LOAD, OR LOAD command in a PLC
program.
319 The value of X, Y, M, T, C contact designation in a PLC program has exceeded its limit.
320
There is an error in the word part of the X, Y, M, T, C contact designation in a PLC
program.
321 No ‘.’ of the X, Y, M, T, C contact designation was commanded in the PLC program.
322
There is an error in the bit part of the X, Y, M, T, C contact designation in the PLC
program.