- 64 -
Chapter 4. PLC Program
9) OUT
(1) Definition
Output the content of the current operation results into a designated content.
The value of the current operation results after executing a command doesn’t change, so
the parallel use of the OUT command is possible.
Output can be designated to output contacts(Y) and auxiliary contacts(M).
(2) Sequence and timing chart
10) D
(1) Definition
Detect the change of an input contact, and then output it for 1 scan time only.
The D command turns ON outputting for 1 scan time only from the instant when an input
contact changes from OFF to ON.
(2) Sequence and timing chart