1.5.3 Antifreeze pr.
04. 07. 2015 10:42
T ON
Glycol type
Tank
5.0°C
Water
Priority tank
1.5.4 Anti-legionellae
04. 07. 2015 10:43
Repetition
T legionellae
t-ON
t-monitor
Activation
1 day
60.0°C
01:00
60min
1.5.5 Cooling funct.
04. 07. 2015 10:43
Activation
Hyst.tank 1
Hyst.tank 2
t-ON
t OFF
2.0K
2.0K
00:00
07:00
PROFESSIONAL MODE
Here, the parameters for tank cooling are
dened.
›t-ON‹ and ›t-OFF‹ are used to dene the
appropriate time slot in which the tank is to
be cooled via the collector, and ›Hyst.tank
1‹ and ›Hyst.tank 2‹ are used to dene the
switch-ON hysteresis.
Continue to scroll.
These parameters must be set by the tter
based on the applicable national regulations.
›Function‹ is used to dene the period in
days (1day - 7days) during which legionella
reduction must have occurred at least once.
›t-ON‹ is used to dene the time of a
possibly required reheating cycle.
›T legionellae‹ denes the disinfection
temperature. ›t monitor‹‹ is used to
dene the minimum disinfection time.
Continue with ›Tank cooling‹.
In the case of plants with two tanks,
the source of the anti-freeze protection
heat must be selected by specifying
›Priority tank‹ or ›Secondary tank‹.
Continue with ›Anti-legionellae‹.