EL Owners Manual – Rev.00 September 2021 22
Cooling loop operating range by temperature and flow rate
Please be aware that the device generates more heat as it degrades. At the beginning of life, a
maximum of 490 W per electrolyser can be extracted from the electrolyte. At the end of life, this value
increases to ca. 700 W per electrolyser. This waste heat is available at up to 50 °C and can then be
used for any customer-specific heating purposes. Depending on the ambient temperature and the
setup of the cooling system, especially the piping, the heat losses from the cooling pipes might be
significant, resulting in a lower heat recovery. The chart is therefore not to be used as an indication of
how much waste heat can be captured for usage.
Warning!
Ensure water pressure on the input line never exceeds 7 barg. This can cause
irreparable damage to the device and create significant leakages. Enapter is
not responsible for any damage or injury resulting from the misuse of Enapter
products.
Ensure the cooling agent pump can supply at least the minimum required
flow rate. Shortage of cooling can cause irreparable damage to the device.
0
5
10
15
20
25
30
35
40
45
50
1 2 3 4 5 6 7
Inlet Temperature [
°C]
Flow Rate [L/min]
Cooling loop operating range