2.3 ADDITIONAL SAFETY FOR THE ELECTROLYSER
The following rules should always be observed. It is the operator’s responsibility to ensure that every
person, working with the device is following these rules:
1. Do not attach filled tanks or other equipment with pressures higher than the device’s maximum
outlet pressure to the H
2
outlet of the device.
2. Do not provide water which does not meet the minimum purity requirements.
3. Do not provide water with a pressure higher than the maximum allowed pressure.
4. Make sure that the H
2
vent line and the O
2
vent line are never obstructed and never combined.
5. Do not combine the O
2
vent line of the EL4.0 with the O
2
vent line or other pipes of older models.