TMT162 Technical data
Endress+Hauser 49
Material
Terminals Cable up to max. 12 AWG
10.0.7 Certificates and approvals
CE mark The measurement system fulfils the requirements demanded by the EU regulations.
Endress+Hauser acknowledges successful unit testing by adding the CE mark.
Ex approval • FM IS, NI Class I, Div. 1+2, Group A, B, C, D
Depending on location install per National Electrical Code (NEC) using wiring methods described
in article 500 through article 510. For Nonincendive installation an intrinsic safety barrier is not
required.
CSA IS, NI Class I, Div. 1+2, Group A, B, C, D
ATEX II1G EEx ia IIC T4/T5/T6
• FM XP, DIP, NI Class I, II, III, Div. 1+2, Group A, B, C, D, E, F, G
CSA XP, DIP, NI Class I,II,III, Div. 1+2, Group A, B, C, D, E, F, G
ATEX II2G EEx d IIC T6
• FM XP, DIP, IS, NI Class I,II,III, Div. 1+2, Group A, B, C, D, E, F, G
CSA XP, DIP, IS, NI Class I,II,III, Div. 1+2, Group A, B, C, D, E, F, G
ATEX EEx d, EEx ia
• FM+CSA XP, DIP, IS, NI Class I,II,III, Div. 1+2, Group A, B, C, D, E, F, G
ATEX II3G EEx nA IIC T4/T5/T6
• ATEX II1/2D
• CSA General Purpose
CSA GP CSA General Purpose
Marine approval GL Ship building approval (Germanischer Lloyd)
UL Recognized component to UL 3111-1
Housing Nameplate
Die-cast aluminum housing AlSi10Mg with powder coating
on polyester basis
1.4301 (AISI 304)
Stainless steel 1.4435 (AISI 316L) 1.4301 (AISI 304)
Stainless steel 1.4435 (AISI 316L) for hygienic applications
(T17 housing)
-