TMT182 6 Commissioning
Endress+Hauser 23
Max primary value
•V9H4
Display the maximum process value. The process value is accepted at the beginning
of the measurement.
! Note!
Max. process value will be changed to the actual process value on access. On reset to
factory default, the default value is entered.
-10000
Default values
•V9H5
Entry: 182 (Reset to factory default settings)
0
Output current
•V9H6
Display of the actual output current signal.
Simulation
•V9H7
Entry of simulation mode.
Entry: Off
On
Off
Current out (sim)
•V9H8
Entry of simulation value (current).
Entry: 3.58 to 21.7 mA
Security locking
•V9H9
Release code for setting up.
Entry: Lock = 0
Release = 281
281
Function group: USER INFORMATION
Tag number
•VAH0
Entry and display of measurement point description (TAG).
Entry: 8 characters
-
Descriptor
•VAH1
Entry and display of plant description.
Entry: 16 characters
-
Hardware Version
•VAH2
Display of unit version,
e.g.: 1.0000 indicates version 1.00.00.
Software Version
•VAH3
7 Software Rev.
Display of software version,
e.g.: 8010 indicates version 1.0.
Serial number
•VAH4
8-digit display of E+H device serial numbers (see legend plates on the device).