EasyManua.ls Logo

Endress+Hauser iTEMP HART TMT182 - Software History; Technical Data; Function and System Design; Input Specifications

Endress+Hauser iTEMP HART TMT182
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Maintenance TMT182
28 Endress+Hauser
9.7 Software history
10 Technical Data
10.1 Function and system design
Measuring principle Electronic monitoring and conversion of input signals in industrial temperature measurement.
Measuring system The temperature head transmitter is a two wire transmitter with an analog output. It has measure-
ment input for resistance thermometers (RTD) in 2-, 3- or 4-wire connection, thermocouples and
voltage transmitters. Setup of the TMT 182 is done using the HART
®
-Protocol with hand operating
module (DXR275, DXR375) or PC (COMMUWIN II or ReadWin
®
2000 operating software).
10.2 Input
Measured variable Temperature (temperature linear transmission behavior), resistance and voltage
Measuring range The transmitter monitors different measuring ranges depending on the sensor connection and input
signals.
Software version / date Changes to software Changes to documentation
V 1.0 / 02.2001 Original software
Compatible with:
•HART
®
Communicator DXR 275
(from OS 4.6) with DevRev 1,
DDRev 1
•Readwin
®
2000
Commuwin II (version 2.07.01-2
and higher)
AMS (version 5.X and higher)
PDM (version 5.2 and higher)
V1.1 / 10.2001 New parameter (V2H1) for selection of
temperature compensation of the cold
junction when using customer specific
linearization of the TC polynom
Compatible with:
•HART
®
Communicator DXR 275
with DevRev 2, DDRev 1
•Readwin
®
2000
Commuwin II (version 2.07.01-4
and higher)
AMS (version 5.X and higher)
PDM (version 5.2 and higher)

Related product manuals