Electrical connection Levelflex FMP55 HART
46 Endress+Hauser
"Power
Supply,
Output"
1)
"Approval"
2)
Terminal
voltage U
at the
device
Maximum load R, depending on the supply voltage U
0
at the supply
unit
C: 2-wire;
4-20mA
HART,
4-20mA
alle Channel 1:
18.5 to
30 V
R [ ]W
[V]U
0
10
18.5 29.5
20 30
0
500
A0014080
Channel 2:
12 to 30 V
R [ ]W
VU
0
[ ]10
12 23
20 30
0
500
A0022583
1) Feature 020 of the product structure
2) Feature 010 of the product structure
Polarity reversal
protection
Yes
Admissible residual ripple
at f = 0 to 100 Hz
U
SS
< 1 V
Admissible residual ripple
at f = 100 to 10000 Hz
U
SS
< 10 mV