EasyManua.ls Logo

Endress+Hauser Levelflex FMP56 - Supply Voltage

Endress+Hauser Levelflex FMP56
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Levelflex FMP56, FMP57
Endress+Hauser 15
4
+
3
2
1
+
1
2
A0013759
1 Terminals switching output
2 Cable entry
Switching output
Function Open collector switching output
Switching behavior Binary (conductive or non-conductive), switches when the programmable switch point is
reached
Failure mode non-conductive
Eectrical connection values U = 10.4 to 35 V
DC
, I = 0 to 70 mA
Insulation voltage floating, Insulation voltage 1 350 V
DC
to power supply aund 500 V
AC
to ground
Switch point freely programmable, separately for switch-on and switch-off point
Switching delay freely programmable from 0 to 100 sec. , separately for switch-on and switch-off point
Number of switching cycles corresponds to the measuring cycle
Signal source
device variables
Level linearized
Distance
Terminal voltage
Electronic temperature
Relative echo amplitude
Number of switching cycles unlimited
Supply voltage
An external power supply is required.
Various supply units can be ordered from Endress+Hauser: see "Accessories" section (® ä 50)
2-wire, 4-20mA HART, passive
"Power Supply, Output"
1)
Outputs Terminal voltage "Approval"
2)
A: 2-wire; 4-20mA HART 1 11.5 to 35 V Non-Ex, Ex nA, CSA GP
11.5 to 32 V Ex ic
11.5 to 30 V Ex ia / IS
13.5 to 30 V Ex d / XP, Ex ic(ia), Ex tD / DIP
C: 2-wire; 4-20mA HART, 4-20mA 1 13.5 to 30 V all
2 12 to 30 V all
1) Feature 020 of the product structure
2) Feature 010 of the product structure
Load (® ä 17)

Table of Contents

Other manuals for Endress+Hauser Levelflex FMP56