EasyManua.ls Logo

Endress+Hauser Levelflex FMP56 - Operating Conditions: Environment; Ambient Temperature Range; Ambient Temperature Limits

Endress+Hauser Levelflex FMP56
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Levelflex FMP56, FMP57
Endress+Hauser 29
Operating conditions: Environment
Ambient temperature range
Measuring device
–40 to +80 °C (–40 to +176 °F)
Local display
–20 to +70 °C (–4 to +158 °F), the readability of the display may be impaired at
temperatures outside the temperature range.
When operating the device in the open with strong sunlight:
Mount the device in a shady position.
Avoid direct sunlight, especially in warmer regions.
Use a weather protection cover (see accessories).
Ambient temperature limits
With a temperature (T
p
) at the process connection the admissible ambient temperature (T
a
) is reduced according
to the following diagram (temperature derating):
Temperature derating for FMP56 with threaded connection G¾ or NPT¾
[°C]([°F]) T
a
[°C]([°F]) T
a
[°C]
([°F])
T
p
[°C]
([°F])
T
p
+120
(+248)
+120
(+248)
+82
(+180)
+79
(+174)
+74
(+165)
-40
(-40)
-40
(-40)
GT20: +74(+165)
GT20: +70(+158)
GT18: +71(+160)
GT18: +68(+154)
GT19: +58(+136)
GT19: +65(+149)
+80(+176)
GT18/20: +79(+174)
GT19: +74(+165)
-40(-40)
-40(-40)
T
a
T
p
4 20mA HART
A:
4 20mA HART
4 20mA
C:
90–253VAC
K:
10.4–48VDC
L:
A0014122
GT18 = stainless steel housing
GT19 = plastic housing
GT20 = aluminum housing
A = 1 current output
C = 2 current outputs
K, L = 4-wire
T
a
= ambient temperature
T
p
= temperature at the process connection

Table of Contents

Other manuals for Endress+Hauser Levelflex FMP56

Related product manuals