Levelflex FMP56, FMP57
50 Endress+Hauser
Accessory Description
WirelessHART Adapter
SWA70
Connects field devices to a WirelessHART network.
The WirelessHART adapter can be mounted directly at a HART device and is easly integrated
into an existing HART network. It ensures safe data transmission and can be operated in
parallel with other wireless networks.
For details refer to Operating Instructions BA061S/04
Accessory Description
Fieldgate FXA320 Gateway for remote monitoring of connected 4-20mA measuring devices via web browser.
For details refer to Technical Information TI025S/04 and Operating Instructions
BA053S/04
Accessory Description
Fieldgate FXA520 Gateway for remote diagnosis and parametrization of connected HART measuring devices
via web browser.
For details refer to Technical Information TI025S/04/xx and Operating Instructions
BA051S/04
Accessory Description
Field Xpert SFX100 Compact, flexible and robust industry handheld terminal for remote parametrization and
measured value inspection via the HART current output (4-20mA).
For details refer to Operating Instructions BA060S/04
Service-specific accessories
Accessory
Description
FieldCare Endress+Hauser's FDT-based Plant Asset Management tool.
Helps to configure and maintain all field devices of your plant. By supplying status
information it also supports the diagnosis of the devices.
For details refer to Operating Instructions BA027S/04 and BA059AS/04
System components
Accessory
Description
Graphic Data Manager
Memograph M
The graphic data manager Memograph M provides information on all the relevant process
variables. Measured values are recorded correctly, limit values are monitored and measuring
points analyzed. The data are stored in the 256 MB internal memory and also on an SD card
or USB stick.
For details refer to Technical Information TI133R/09 and Operating Instructions
BA247R/09
RN221N Active barrier with power supply for safe separation of 4 to 20 mA current circuits. Provides
bi-directional HART transmission.
For details refer to Technical Information TI073R/09 and Operating Instructions
BA202R/09
RNS221 Transmitter supply for 2-wire sensors or transmitters exclusively for non-Ex areas. Provides
bi-directional communication using the HART communication sockets.
For details refer to Technical Information TI081R/09 and Operating Instructions
KA110R/09