Liquicap M FTI51, FTI52 Installation
Endress+Hauser 27
Support for marine approval (GL)
Fully insulated rod probes can be supported conductively or non-conductively.
Partially insulated rod probes may only be supported with insulation at the uninsulated probe end.
!
Note!
Rod probes with a diameter of 10 mm and 16 mm, do not have to be supported with a length
1m.
Rod probes with a diameter of 10 mm and 16 mm, have to be supported with a length 1m
(see drawing).
L00-FMI5xxxx-06-05-xx-xx-077
Example for calculating distances:
Probe length L = 2000 mm.
L/4 = 500 mm
L/2 = 1000 mm
Measured from the end of the probe rod = 300 mm.
L/4
L/2
L
300 mm