Liquicap M FTI51, FTI52 Technical data
Endress+Hauser 87
For process connections 1½", flanges > DN50, > ANSI 2", > JIS10K
Rod insulation: PTFE, PFA
Rope insulation: FEP, PFA
!
Note!
Refer also to the "Process connections" subchapter in the "Installation" chapter.
L00-FMI5xxxx-05-05-xx-xx-010
P
p
: Process pressure
T
p
: Process temperature
With a fully insulated inactive length (22 mm rod) and active buildup compensation with
16 mm rod:
L00-FMI5xxxx-05-05-xx-xx-012
P
p
: Process pressure
T
p
: Process temperature
!
Note!
In the case of flange process connections, the maximum pressure is limited by the nominal pressure
of the flange.
bar
P
p
0
0
–40 –20–60
80 120 160 180
60
40
80
20
–80
+200/
–1
20 40 60 100 140
+200/
+20
+80/
+60
+40/
+100
T
P
°C
100
bar
P
p
0
0
–40 –20–60
80 120 160 180
60
40
20
–80
+200/
–1
20 40 60 100 140
+200/
+2
+50/
+50
T
P
°C