Functional Safety Manual
for the Memosens transmitter Liquiline M CM42 SIL
Version: Page:
2.0
70 of 72
Alle Recht
e vorbehalten. Das Kopieren dieses Dokuments und die Verwendung von Teilen aus diesem Dokument ist
ohne schriftliche Genehmigung der Endress+Hauser Conducta GmbH+Co. KG nicht erlaubt.
All rights reserved. Passing on and copying of this document, use and communication of its contents not
permitted without written authorization from Endress+Hauser Conducta GmbH+Co. KG.
*1
According to Siemens SN29500 at 60°/100° Celsius – 140°F/212°F. MTBF
calculated as reciprocal of PFH/
Total
.
*2
During this time all diagnostic functions are completed at least once.
*3
Time between failure detection and failure reaction.
*4
Of course, you can choose different (e.g. longer) proof test intervals. Choose the
one suited for your application.
Note!
These values do NOT include the PFD
avg
/SFF values of the used voter and the sensor
element in contact with the medium. Nor does it take into account any medium
interactions with the sensor element.