Micropilot FMR67B PROFINET with Ethernet-APL
44 Endress+Hauser
Antenna flush mount, PTFE, 80 mm (3 in), with standard flange and purge air connection
R
L2
L1
L3
L4
!62.5 (2.46)
A
B
1
1
25.5 (1.0)
A0046489
 51 Dimensions of antenna flush mount, PTFE, 80 mm (3 in), with standard flange and purge air connection .
Unit of measurement mm (in)
A Process temperature version ≤150 °C (302 °F)
B Process temperature version ≤200 °C (392 °F)
R Reference point of measurement
1 Bottom edge of housing
L1 158 mm (6.22 in); version with Ex d or XP approval +5 mm (+0.20 in)
L2 Variable dimension due to flange thickness (standard flange)
L3 Variable dimension due to flange thickness (standard flange)
L4 170 mm (6.69 in); version with Ex d or XP approval +5 mm (+0.20 in)
The flange dimensions depend on the selected standard and sealing surface (order options).
Dimensions that deviate from the standard are indicated.