Micropilot FMR67B PROFINET with Ethernet-APL Technical data
Endress+Hauser 75
Media Redundancy Protocol
(MRP)
Yes
System redundancy support System redundancy S2 (2 AR with 1 NAP)
Device profile Application interface identifier 0xB321
Generic device
Manufacturer ID 0x11
Device type ID 0xA1C1
Device description files (GSD,
FDI, DTM, DD)
Information and files available at:
www.endress.com
On the product page for the device: Documents/Software → Device drivers
www.profibus.org
Supported connections 2 x AR (IO Controller AR)
1 x AR (IO-Supervisor Device AR connection allowed)
1 x Input CR (Communication Relation)
1 x Output CR (Communication Relation)
1 x Alarm CR (Communication Relation)
Configuration options for
device
Manufacturer-specific software (FieldCare, DeviceCare)
Web browser
Device master file (GSD), can be read out via the integrated Web server of
the device
DIP switch for setting the service IP address
Configuration of the
device name
DCP protocol
Process Device Manager (PDM)
Integrated Web server
Supported functions Identification & maintenance
Simple device identification via:
Control system
Nameplate
Measured value status
The process variables are communicated with a measured value status
Blinking feature via the local display for simple device identification and
assignment
Device operation via operating tools (e.g., FieldCare, DeviceCare, SIMATIC
PDM)
System integration For information on system integration, see Operating Instructions
Cyclic data transmission
Overview and description of the modules
Status coding
Startup configuration
Factory setting
15.3 Environment
Ambient temperature
range
The following values apply up to a process temperature of +85 °C (+185 °F). At higher
process temperatures, the permitted ambient temperature is reduced.
Without LCD display:
Standard: –40 to +85 °C (–40 to +185 °F)
With LCD display: –40 to +85 °C (–40 to +185 °F) with limitations in optical properties
such as display speed and contrast for example. Can be used without limitations up to
–20 to +60 °C (–4 to +140 °F)
If operating outdoors in strong sunlight:
Mount the device in the shade.
Avoid direct sunlight, particularly in warm climatic regions.
Use a weather protection cover (see accessories).