Nivector FTI26 Installation
Endress+Hauser 13
≥20 (0.8)
G 1"
A0036360
 5 Where buildup occurs on the silo wall with internal G 1" threaded adapter
≥20 (0.8)
G 1"
A0036359
 6 Bore hole in silo wall with lock nuts, can be ordered as an accessory
13.5 (0.53)
G 1"
A0036362
 7 Installation with weld-in adapter, can be ordered as an accessory
NOTICE
Installation in a conventional T-section or in a metallic tank nozzle reduces the
measuring performance of the sensor.
Install Tri-Clamp version, e. g. NA Connect adapter for hygiene-compliant connection. This
minimizes dead legs and increases cleanability.