Tankside Monitor NRF81 Operating menu
Endress+Hauser 129
Description Defines which HART variable is the pressure.
Selection No value
Primary variable (PV)
Secondary variable (SV)
Tertiary variable (TV)
Quaternary variable (QV)
Factory setting No value
Additional information
Read access Operator
Write access Maintenance
Output density
Navigation  Setup → Advanced setup → Input/output → HART devices → HART Device(s)
→ Output density
Prerequisite Not available for Micropilot S FMR5xx and Prothermo 53x. (In these cases the measured
variables are allocated automatically).
Description Defines which HART variable is the density.
Selection No value
Primary variable (PV)
Secondary variable (SV)
Tertiary variable (TV)
Quaternary variable (QV)
Factory setting No value
Additional information
Read access Operator
Write access Maintenance
Output temperature
Navigation  Setup → Advanced setup → Input/output → HART devices → HART Device(s)
→ Output temperature
Prerequisite Not available for Micropilot S FMR5xx and Prothermo 53x. (In these cases the measured
variables are allocated automatically).
Description Defines which HART variable is the temperature.
Selection No value
Primary variable (PV)
Secondary variable (SV)
Tertiary variable (TV)
Quaternary variable (QV)