Proline Promag 50P, 53P
22 Endress+Hauser
Limiting flow The diameter of the pipe and the flow rate determine the nominal diameter of the sensor. The optimum velocity
of flow is 6 to 10 ft/s (2 to 3 m/s). The velocity of flow (v), moreover, has to be matched to the physical prop-
erties of the medium:
• v < 6 ft/s (2 m/s): for abrasive mediums such as potter's clay, lime milk, ore slurry etc.
• v > 6 ft/s (2 m/s): for accretive mediums such as wastewater sludge, etc.
Flow characteristics (SI units)
Nominal
diameter
Recommended
flow rate
Factory settings
[mm] [inch]
Min./max. full scale value
(v ~ 0.3 or 10 m/s)
Full scale value
(v ~ 2.5 m/s)
Pulse weighting
(~ 2 pulse/s)
Creepage
(v ~ 0.04 m/s)
15 1/2" 4…100 dm
3
/min 25 dm
3
/min 0.20 dm
3
0.5 dm
3
/min
25 1" 9…300 dm
3
/min 75 dm
3
/min 0.50 dm
3
1dm
3
/min
32 1 1/4" 15…500 dm
3
/min 125 dm
3
/min 1.00 dm
3
2dm
3
/min
40 1 1/2" 25…700 dm
3
/min 200 dm
3
/min 1.50 dm
3
3dm
3
/min
50 2" 35…1100 dm
3
/min 300 dm
3
/min 2.50 dm
3
5dm
3
/min
65 2 1/2" 60…2000 dm
3
/min 500 dm
3
/min 5.00 dm
3
8dm
3
/min
80 3" 90…3000 dm
3
/min 750 dm
3
/min 5.00 dm
3
12 dm
3
/min
100 4" 145…4700 dm
3
/min 1200 dm
3
/min 10.00 dm
3
20 dm
3
/min
125 5" 220…7500 dm
3
/min 1850 dm
3
/min 15.00 dm
3
30 dm
3
/min
150 6" 20…600 m
3
/h 150 m
3
/h 0.025 m
3
2.5 m
3
/h
200 8" 35…1100 m
3
/h 300 m
3
/h 0.05 m
3
5.0 m
3
/h
250 10" 55…1700 m
3
/h 500 m
3
/h 0.05 m
3
7.5 m
3
/h
300 12" 80…2400 m
3
/h 750 m
3
/h 0.10 m
3
10 m
3
/h
350 14" 110…3300 m
3
/h 1000 m
3
/h 0.10 m
3
15 m
3
/h
400 16" 140…4200 m
3
/h 1200 m
3
/h 0.15 m
3
20 m
3
/h
450 18" 180…5400 m
3
/h 1500 m
3
/h 0.25 m
3
25 m
3
/h
500 20" 220…6600 m
3
/h 2000 m
3
/h 0.25 m
3
30 m
3
/h
600 24" 310…9600 m
3
/h 2500 m
3
/h 0.30 m
3
40 m
3