Pressure loss No pressure loss if the sensor is installed in a pipe of the same nominal diameter.
Pressure losses for configurations incorporating adapters to DIN EN 545 Page 18
Flow characteristics (US units)
Nominal
diameter
Recommended
flow rate
Factory settings
[inch] [mm]
Min./max. full scale value
(v ~ 1 or ~ 33 ft/s)
Full scale value
(v ~ 8 ft/s)
Pulse weighting
(~ 2 pulse/s)
Creepage
(v ~ 0.1 ft/s)
1/2" 15 1.0 to 27 gal/min 6 gal/min 0.05 gal 0.10 gal/min
1" 25 2.5 to 80 gal/min 18 gal/min 0.20 gal 0.25 gal/min
1 1/4" 32 4 to 130 gal/min 30 gal/min 0.20 gal 0.50 gal/min
1 1/2" 40 7 to 190 gal/min 50 gal/min 0.50 gal 0.75 gal/min
2" 50 10 to 300 gal/min 75 gal/min 0.50 gal 1.25 gal/min
2 1/2" 65 16 to 500 gal/min 130 gal/min 1 gal 2.0 gal/min
3" 80 24 to 800 gal/min 200 gal/min 2 gal 2.5 gal/min
4" 100 40 to 1250 gal/min 300 gal/min 2 gal 4.0 gal/min
5" 125 60 to 1950 gal/min 450 gal/min 5 gal 7.0 gal/min
6" 150 90 to 2650 gal/min 600 gal/min 5 gal 12 gal/min
8" 200 155 to 4850 gal/min 1200 gal/min 10 gal 15 gal/min
10" 250 250 to 7500 gal/min 1500 gal/min 15 gal 30 gal/min
12" 300 350 to 10,600 gal/min 2400 gal/min 25 gal 45 gal/min
14" 350 500 to 15,000 gal/min 3600 gal/min 30 gal 60 gal/min
16" 400 600 to 19,000 gal/min 4800 gal/min 50 gal 60 gal/min
18" 450 800 to 24,000 gal/min 6000 gal/min 50 gal 90 gal/min
20" 500 1000 to 30,000 gal/min 7500 gal/min 75 gal 120 gal/min
24" 600 1400 to 44,000 gal/min 10,500 gal/min 100 gal 180 gal/min