Installation Proline Prosonic Flow 91W
16 Endress+Hauser
2.7.2 Installing Prosonic Flow W (DN 50 to 400 0 / 2" to 160")
Installation for measurement via one traverse (DN 600 to 2000 /24" to 80")
Prerequisites
The installation distances (sensor distance and wire length) are known ä 8.
The strapping bands are already mounted ä 10.
Material
The following material is needed for mounting:
Two strapping bands incl. mounting bolts and centering plates where necessary
(already mounted ä 10)
Two measuring wires, each with a cable lug and a fixer to position the strapping bands
Two sensor holders
Coupling fluid for an acoustic connection between the sensor and pipe
Two sensors incl. connecting cables.
Procedure
1.
Prepare the two measuring wires:
Arrange the cable lugs and fixer such that the distance they are apart corresponds to the
wire length (SL).
Screw the fixer onto the measuring wire.
A0001112
Fig. 13: Fixer (a) and cable lugs (b) at a distance that corresponds to the wire length (SL)
2. With the first measuring wire:
Fit the fixer over the mounting bolt of the strapping band that is already securely
mounted.
Run the measuring wire cl
ockwise around the pipe.
Fit the cable lug over the mounting bolt of the strapping band that can still be moved.
3. With the second measuring wire:
Fit the cable lug over the mounting bolt of the strapping band that is already securely
mounted.
Run the measuring wire co
unterclockwise around the pipe.
Fit the fixer over the mounting bolt of the strapping band that can still be moved.
1234567891011
SL