Operation RIA45
14 Endress+Hauser
Installing the communication DTM in FieldCare
Before the indicator can be configured, FieldCare Device Setup must be installed on your PC.
The installation instructions can be found in the FieldCare instructions.
Then install the FieldCare device driver according to the following instructions:
1. First install the device driver "CDI DTMlibrary" in FieldCare. It can be found in FieldCare
under "Endress+Hauser Device DTMs → Service / Specific → CDI".
2. The DTM catalog in FieldCare must then be updated. Add the new installed DTMs to the
DTM catalog.
Installation of the Windows driver for TXU10/FXA291
Administrator rights are required to install the driver in Windows. Proceed as follows:
1. Connect the device to the PC using the TXU10/FXA291 interface adapter.
A new device is detected and the Windows installation wizard opens.
2. In the installation wizard, do not allow the device to automatically search for software.
For this, select "No, not this time" and click "Next".
3. In the next window, select "Install software from a list or specific location" and click
"Next".
4. In the next window, click "Browse" and select the directory where the driver for the
TXU10/FXA291 adapter is saved.
The driver is installed.
5. Click "Finish" to finish the installation.
6. Another device is detected and the Windows installation wizard starts again. Again,
choose "No, not this time" and click "Next".
7. In the next window, select "Install software from a list or specific location" and click
"Next".
8. In the next window, click "Browse" and select the directory where the driver for the
TXU10/FXA291 adapter is saved.
The driver is installed.
9. Click "Finish" to finish the installation.
This completes the driver installation for the interface adapter. The COM port that has been
assigned can be seen in the Windows device manager.
Establishing the connection
Proceed as follows to establish the connection with FieldCare:
1. Firstly, edit the connection macro. For this, start a new project and in the window that is
displayed, right-click the symbol for "Service (CDI) FXA291" and select "Edit".
2. In the next window, to the right of "Serial interface", select the COM port which was
assigned during the installation of the Windows driver for the TXU10/FXA291 adapter.
The macro is now configured. Select "Finish".