Mounting RIA45
8 Endress+Hauser
Panel cutout: 92 mm (3.62 in) x 45 mm (1.77 in).
Panel thickness: max. 26 mm (1 in).
Max. viewing angle range: 45° to the left and right from the central display axis.
If the devices are arranged horizontally beside one another in the X-direction, or arranged
vertically on top of one another in the Y-direction, the mechanical distance (specified by the
housing and front section) must be observed.
4.3 Mounting procedure
The necessary panel cutout is 92 mm (3.62 in) x 45 mm (1.77 in)
114
67
12
1.
3
4
2.
4
3
5
6
6
A0010404
 1 Installation in a panel
1. Screw the threaded rods (item 1) into the positions provided on the mounting frame
(item 2). Four opposing screw positions (item 3/4) are available for this purpose.
2. Push the device through the panel cutout from the front.
3. To secure the casing in the panel, hold the device level and push the mounting frame
(item 2), with the threaded rods screwed in, over the casing until the frame locks into
position (1).
4. Then tighten the threaded rods to fix the device in place (2.).
5. For the Ex option, mount the spacer (item 6) for the terminals.
To remove the device, the mounting frame can be unlocked at the locking elements (item 5)
and then removed.