Operation Soliswitch FTE20
18 Endress+Hauser
*Option
A0017353
 13 Inspection glass to observe rotational movement
6.3 Indicator light (optional)
The point level switch is optionally fitted with an indicator light that lights up when the rotary
paddle stops.
6.4 Testing the internal switch
When the housing cover is open, the function of the internal switch to switch off the motor
can be checked by inserting a screwdriver into the opening provided in the electronics cover
and by moving the handle in the direction of the arrow.
A0017369
 14 Testing the internal switch