EasyManua.ls Logo

envea STACK 710 - Page 39

envea STACK 710
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
STACK 710 4 Getting Started
ENVEA UK Ltd (PC-000878-MA Issue 7, December 2021) 39
51
Number of
faults
Indicates the
number of faults
currently present
(regardless of
mask states)
0 - 32
NA
52
Error Flags
Error flags
Bit 0 = Zero motor jammed Bit
1 = Upscale motor jammed Bit
2 = Source LED fail
Bit 3 = Flood Led fail Bit 4 =
ADC over-range Bit 5 = ADC
fault
Bit 12 = Negative opacity Bit
13 = Checksum error
Bit 14 = Lens contamination
limit
Bit 15 = Failure during
calibration
NA
201
Average
during audit
0 = Off
1 = On
NA
202
Initiate
Calibration
Bit 0 = Cal check
Bit 1 = Cal audit
NA
95
Cal check
interval
In hours (Default =
24)
0 - 1000
NA
96
Time to
next cal
Time to next cal in
minutes
0 - 65535
NA
Note: Read operation on an unassigned Register will return zero rather than an exception.